Requirements for dividing commercial premises
The resulting premises must comply with municipal planning provisions, the CTE and the sector-specific regulations applicable to their activity. These references apply to the municipality of Madrid; in other municipalities, we check their own rules. In existing buildings, we justify the extent of the requirements and, where applicable, the solutions for effective compliance permitted by the regulations.
1 Feasibility and permitted use:
For all commercial premises, it is necessary to verify that the use or activity is permitted. Most uses are compatible or admissible on the ground floor, but every case must be checked in detail, as some areas have restrictions according to the activity, such as restaurants or workshops. On first and higher floors, unless the premises are offices, professional practices or consulting rooms, their entrance must be independent of the residential entrance hall.
The Licensing Management Agency (AGLA) will verify the feasibility of the new activity and its requirements. We handle this procedure for you.
2 Requirements for the premises: heights, stairs, basements and mezzanines.
a) Minimum clear height: the NNUU generally require 2.50 m in habitable rooms and 2.20 m in non-habitable rooms, without prejudice to the requirements for each use. Workplace regulations require 3 m, with a reduction to 2.50 m permitted in commercial premises, service premises, offices and professional practices. We check the planning and workplace requirements applicable to each area.
b) Mezzanines and basements: we review their planning status, whether the proposed use is permitted, and the requirements for height, ventilation, accessibility and evacuation. Their inclusion in an earlier licence does not automatically authorise any new use. If they have no authorisation, we check whether retrospective approval is possible under the planning rules.
c) Stairs: must meet minimum dimensions:
– General-use stairs: a minimum going of 28 cm and a rise of between 13 and 18.5 cm; in public-use areas, or where no alternative lift is available, the maximum rise is 17.5 cm. The width is calculated according to the use, users and evacuation requirements; there is no universal minimum of 100 cm for all commercial premises. Accessibility and workplace safety requirements are also checked.
– Restricted-use stairs: the CTE permits a minimum width of 80 cm, a minimum going of 22 cm and a maximum rise of 20 cm only in areas meeting its definition of restricted use, not simply because the public is excluded. Minimum clear headroom is 2.20 m generally and 2.10 m for restricted use, without prejudice to the 2.20 m required by workplace regulations for stairs in workplaces.
3 Accessibility and access route:
An accessible route must generally have a minimum clear width of 1.20 m, with no steps, and doors providing a minimum clear opening of 80 cm. Local narrowing and other conditions must be justified under the CTE. In existing buildings, we study accessibility solutions and, where applicable, the justified effective compliance permitted by the regulations.
4 Toilets:
The provision of toilets and, where relevant, a toilet lobby depends on the activity, occupancy and health and workplace regulations. Where toilets are mandatory, the CTE requires at least one accessible toilet for every 10 WCs or fraction thereof, which may be shared by both sexes. The extent of adaptation in existing buildings must be justified; there is no general exemption for businesses with 50 employees or fewer.
5 Protection and heritage status: BIC, BIP and CPPHAN
Most buildings in historic centres have some degree of protection: partial, structural or comprehensive, in addition to designations as assets of cultural or heritage interest. The quickest and most advisable approach is to carry out work in keeping with their original condition, without alterations. However, several situations may arise:
– The protected element is in its original condition and no work is carried out on it: its protection status does not affect the work.
– The protected element is not in its original condition: restoration in accordance with the general criteria and the Heritage Commission’s requirements is recommended.
– Work is carried out on the protected element, or it is not restored to its original condition: a prior opinion and report from the Commission for the Protection of Historical, Artistic and Natural Heritage (CCPHAN) will be required. This is a more complex process.
6 Ventilation, smoke extraction, boilers and ovens:
Commercial premises must have ventilation appropriate to their use. In Madrid, separation distances for ventilation and air-conditioning outlets are determined by airflow and the position of receiving openings, under Annex II of the Air Quality and Sustainability Ordinance. For example, for flows from 0.2 to 1 m³/s: 2 m from openings on the same wall, 3.5 m from openings opposite in the circumstances defined by the ordinance, and 1.5 m in all other situations. The minimum height above circulation areas is 2.5 m, reducible to 2 m for flows below 0.2 m³/s.
Where smoke extraction to roof level is required, its height and separation distances must be calculated under the Air Quality and Sustainability Ordinance. On flat roofs or roofs with a slope below 20°, the duct must rise 1 m above the roofs of buildings within a radius of 15 m for outputs of up to 700 kW; the radius increases to 50 m for higher outputs. Obstacles and steeper roofs have specific rules. For boilers and water heaters, the RITE establishes discharge at roof level as the general solution: outlets through façades or into courtyards are permitted only in the expressly specified circumstances, for room-sealed gas appliances of up to 70 kW or natural-draught domestic hot water appliances of up to 24.4 kW. Alterations to existing systems without a suitable roof-level duct must also meet the relevant conditions, including NOx class 5 for individual boilers covered by the exception, and municipal regulations.
The municipal exception to discharge at roof level requires all appliances to be electric and to cook internally without releasing odours, with a combined nominal useful output of 4 kW or less, adequate maintenance and no openings to the outside except those required by sector-specific regulations. If odours nevertheless occur, the local council may require additional measures or discharge at roof level.
7 Fire safety:
These regulations can be summarised as follows:
– Escape corridors are sized according to occupancy, with a general minimum width of 1 m. The CTE permits 80 cm for a maximum of 10 regular users, but this exception does not reduce the widths required by accessibility or other applicable regulations, such as workplace rules.
– The permitted escape distance depends on the use, occupancy and number of exits. As a guide, where a single exit is permitted, the general limit is 25 m to the storey or room exit; this is not a universal rule of 25 m to the street. We check the conditions and exceptions in Table 3.1 of DB SI.
– Escape routes from evacuation starting points to a safe external space must have the emergency lighting required by the CTE.
– The fire protection equipment required for the use and floor area must be installed. In general, portable extinguishers must have a minimum rating of 21A-113B and be within a travel distance of 15 m from any evacuation starting point on the floor. Automatic kitchen fire suppression is required where the installed power exceeds 50 kW; for Hospital or Public Residential use, the threshold is 20 kW. The system must protect the cooking appliances: simply referring to the smoke extraction outlet is not sufficient.